Binder CO2 Incubators with Hot Air Sterilization | CB-S 260

Stock Code
CB-S 260
Warranty Period
24 Month
Benefits
• Safe – cell cultures receive maximum protection against contamination.
Reliable – constant well-being conditions for the cells.
Smart – simple routine cleaning and convenient operation.
Economical – efficient operation without consumables.
binder, binder sales, binder azerbaycan
Binder CO2 Incubators with Hot Air Sterilization | CB-S 260

   The durable and affordable CB-S series incubators are suitable for routine cell cultivation applications in the field of cell production, particularly in academic settings. They are contamination-proof due to 180°C hot air sterilization and reliably pH-stable thanks to the drift-free infrared CO₂ measurements conducted in real time.

Binder CO2 Incubators with Hot Air Sterilization | CB-S 170

Binder CO2 Incubators with Hot Air Sterilization | CB-S 260 General Information

- Temperature Range:+6°C above ambient temperature to +50°C
- Humidity range: 90 to 95% RH
- CO₂ control range: 0 to 20 vol.% CO₂
- Tried-and-tested anti-contamination concept with 180°C hot air sterilization
- Humidification system with condensation protection
- CO2 gas mixing jet with Venturi effect
- CO2 sensor with infrared technology
- LCD to display temperature and CO2 along with additional information and alarms
- Internal data logger, measured values can be read out in open format via USB
- Tightly fitted inner door made of safety glass
- Seamless stainless steel inner chamber
- Perforated shelves, stainless steel
- Troubleshooting system with visual and acoustic alarms
- Interfaces: Ethernet, USB, zero-voltage alarm contact

- Units can be stacked with stacking adapters; the CB-S is suitable for stacking with CB and CBF models of the same size

Data

Designation

CBS260-230V

CBS260UL-120V

Article Number 9640-0003 9640-0004
Option model Standard Standard


With Access port 30 mm left
Designation

CBS260-230V

CBS260UL-120V

Temperature range +6 °C above ambient temperature to 50 °C +6 °C above ambient temperature to 50 °C
Temperature uniformity at 37°C 0.4 ± K 0.4 ± K
Temperature fluctuation at 37°C 0.1 ± K 0.1 ± K
Recovery time after door was opened for 30 s at 37°C 8 min 8 min

Performance Data Climate

Designation

CBS260-230V

CBS260UL-120V

Humidity range 90 ...95 % RH 90 ...95 % RH

Gas Data

Designation

CBS260-230V

CBS260UL-120V

CO₂ range 0 ...20 Vol.-% CO2 0 ...20 Vol.-% CO2
CO₂ measuring technology IR IR
CO₂ recovery time after door was opened for 30 s at 5 vol. % CO₂ 5 min 5 min


Electrical Data

Designation

CBS260-230V

CBS260UL-120V

Rated Voltage 200...230 V 100...120 V
Power frequency 50/60 Hz 50/60 Hz
Nominal power 1,5 kW 1,5 kW
Unit fuse 10,0 A 16,0 A
Phase (Nominal voltage) 1~ 1~

Fixtures

Designation

CBS260-230V

CBS260UL-120V

Number of shelves (std./max.) 2/8 2/8


Binder CO2 Incubators with Hot Air Sterilization | CB-S 260 Images

Binder CO2 Incubators with Hot Air Sterilization | CB-S 170Binder CO2 Incubators with Hot Air Sterilization | CB-S 170Binder CO2 Incubators with Hot Air Sterilization | CB-S 170
Binder CO2 Incubators with Hot Air Sterilization | CB-S 260 CB-S 260
Binder CO2 Incubators with Hot Air Sterilization | CB-S 260