Binder Dynamic Climate Chambers | MK 56

Stock Code
KBF 720
Benefits
  • Safe thanks to climatic homogeneity that far exceeds the accuracy required by ICH guidelines, even with a fully loaded unit.
  • Reliable thanks to failsafe operation without compromise. The interior and Longlife evaporator plate are made entirely from stainless steel. 
  • Smart, as a wide range of accessories makes it highly compatible for adaptation to specific customer requirements.
  • Economical thanks to maximum effective volume which allows for 30% larger load compared to the competition.
binder, binder sales, binder azerbaycan
Binder Dynamic Climate Chambers | MK 56

  The BINDER MK series chamber is suitable for all heat and cold tests between -40 °C and 180 °C. The MK is a clever alternative to complex individual solutions for cyclical temperature tests.

MK_056

 

Binder Dynamic Climate Chambers | MK 56 General Information

- Temperature range: -40°C above ambient temperature to +180 °C
- APT.line™ preheating chamber technology
- Programmable condensation protection for test material
- Heated viewing window with LED interior lighting
- BINDER Multi Management Software APT-COM™ Basic Edition
- Troubleshooting system with visual and audible alarms
- Intuitive touchscreen controller with time-segment and real-time programming
Internal data logger, measured values can be read out in open format via USB
- Unit self-test for comprehensive status analysis
- Access port with silicone plug, 50 mm, left
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
- 4 castors, two with brakes
Computer interface: Ethernet
- Adjustable ramp function
-
Integrated chart recorder
- Real-time clock
- 1 stainless steel rack
- Inner chamber made of stainless steel
- CFC-free refrigerant R-452A
- Cooling with compressor cooling unit


Binder Constant Climate Chambers | KBF 720 General Information
Data

Designation

MK056-230V

MK056-240V

Article Number 9020-0374 9020-0388
Option model

Standard

Standard

Performance Data Temparature
Designation

MK056-230V

MK056-240V

Temperature range -40...180 °C -40...180 °C
Temperature uniformity dependent on set value 0.5...1.5 ± K 0.5...1.5 ± K
Temperature fluctuation dependent on set value 0.1...0.5 ± K 0.1...0.5 ± K
Average heating-up rate according to IEC 60068-3-5 5.0 K/min 5.0 K/min
Cooling down time from 180°C to -40°C 90 min 90 min
Average cooling down time according to IEC 60068-3-5 5.0 K/min 5.0 K/min
Electrical Data
Designation

MK056-230V

MK056-240V

Rated Voltage 230 V 240 V
Power frequency 50 Hz 60 Hz
Nominal power 2,8 kW 2,8 kW
Unit fuse 16,0 A 16,0 A
Phase (Nominal voltage) 1~ 1~
Measures
Designation

MK056-230V

MK056-240V

Interior volume 60 L 60 L
Net weight of the unit (empty) 165 kg 165 kg
Load per rack 15 kg 15 kg
Permitted load 60 kg 60 kg
Wall clearance back 300 mm 300 mm
Wall clearance sidewise 200 mm 200 mm

Housing dimensions not incl. fittings and connections

Designation KBF720-230V KBF720UL-240V
Width net 1,250 mm 1,250 mm
Height net 1,925 mm 1,925 mm
Depth net 890 mm 890 mm
Internal Dimensions
Designation KBF720-230V KBF720UL-240V
Interior width 973 mm 973 mm
Interior height 1,250 mm 1,250 mm
Interior depth 576 mm 576 mm
Inner doors 2 2
Unit doors 2 2

Environment Specific Data
Designation KBF720-230V KBF720UL-240V
Sound-pressure level 53 dB(A) 53 dB(A)
Energy consumption at 40°C and 75% RH 620 Wh/h 620 Wh/h
Fixtures
Designation KBF720-230V KBF720UL-240V
Number of shelves (std./max.) 2/15 2/15
Binder Constant Climate Chambers | KBF 720 Images

Binder Constant Climate Chambers | KBF 720Binder Constant Climate Chambers | KBF 720Binder Constant Climate Chambers | KBF 720

Binder Dynamic Climate Chambers | MK 56 KBF 720
Binder Dynamic Climate Chambers | MK 56

Recommend

*
*
*