Binder Dynamic Climate Chambers | MKF 115

Stock Code
MKF 115
Benefits
  • Homogeneous climate conditions thanks to APT.line™ technology
  • Automatic water and wastewater management
  • Pressure humidification with fast response times
  • Comprehensive programming and data acquisition
  • Large heated viewing window
binder, binder sales, binder azerbaycan
Binder Dynamic Climate Chambers | MKF 115

  A BINDER MKF series environmental simulation chamber is ideally suited for any cold and heat testing based on current temperature and climate testing methods according to DIN and IEC standards. The comprehensive standard equipment for this environmental simulation chamber ensures ease of operation.

Binder Dynamic Climate Chambers | MKF 115

 

Binder Dynamic Climate Chambers | MKF 115 General Information

- Temperature range: -40°C above ambient temperature to +180 °C
Humidity range: 10 % to 98 % RH
4 zero-voltage relay contacts that can be activated via MCS controller
- APT.line™ preheating chamber technology
- Programmable condensation protection for test material
- Heated viewing window with LED interior lighting
- Humidity regulation with capacitative humidity sensor and vapor humidification
- BINDER Multi Management Software APT-COM™ Basic Edition
Troubleshooting system with visual and audible alarms
- Intuitive touchscreen controller with time-segment and real-time programming
- Internal data logger, measured values can be read out in open format via USB
- Unit self-test for comprehensive status analysis
Access port with silicone plug: 50 mm, left
4 castors, two with brakes
Computer interface: Ethernet
Adjustable ramp function
- Integrated chart recorder
- Real-time clock
- Door heating
- 1 stainless steel rack
- Complete safety connection kit for water supply and drainage, up to 1 m height
- BINDER test confirmation
- Inner chamber made of stainless steel
- Pt 100 temperature sensor
- Thermal insulation using PUR foam
- CFC-free refrigerant R-452A
- Cooling with compressor cooling unit
- Fin evaporator
- Complete safety connection kit for water supply and drainage, up to 1 m height


Binder Constant Climate Chambers | MKF 115 General Information
Data

Designation MKF115-400V MKF115-480V-C
Article Number 9020-0379 9020-0357
Option model

Standard

with voltage and frequency converter

Performance Data Temparature
Designation MKF115-400V MKF115-480V-C
Temperature range -40...180 °C -40...180 °C
Temperature uniformity dependent on set value 0.1...1.3 ± K 0.1...1.3 ± K
Temperature fluctuation dependent on set value 0.1...0.6 ± K 0.1...0.6 ± K
Average heating-up rate according to IEC 60068-3-5 5.5 K/min 5.5 K/min
Cooling down time from 180°C to -40°C 100 min 100 min
Average cooling down time according to IEC 60068-3-5 4.5 K/min 4.5 K/min

Performance Data Climate
Designation MKF115-400V MKF115-480V-C
Temperature range with humidity 10...95 °C 10...95 °C
Humidity range 10...98 % RH 10...98 % RH
Temperature fluctuation with humidity dependent on set value 0.1...1.3 ± K 0.1...1.3 ± K
Humidity fluctuation with humidity dependent on set value ≤2,5 ± % r.F. ≤2,5 ± % r.F.
Max. heat compensation at 25°C and 90% RH 400 W 400 W
Electrical Data
Designation MKF115-400V MKF115-480V-C
Rated Voltage 400 V 480 V
Power frequency 50 Hz 60 Hz
Nominal power 4,8 kW 4,8 kW
Unit fuse 16,0 A 16,0 A
Phase (Nominal voltage) 3~ 3~

Measures

Designation MKF115-400V MKF115-480V-C
Interior volume 115 L 115 L
Net weight of the unit (empty) 280 kg 280 kg
Load per rack 30 kg 30 kg
Permitted load 60 kg 60 kg
Wall clearance back 300 mm 300 mm
Wall clearance sidewise
200 mm 200 mm
Housing dimensions not incl. fittings and connections
Designation MKF115-400V MKF115-480V-C
Width net 980 mm 980 mm
Height net 1,725 mm 1,725 mm
Depth net 865 mm 865 mm
Internal Dimensions
Designation MKF115-400V MKF115-480V-C
Interior width 600 mm 600 mm
Interior height 480 mm 480 mm
Interior depth 400 mm 400 mm
Unit doors 1 1
Environment-specific data
Designation MKF115-400V MKF115-480V-C
Sound-pressure level 62 dB(A) 67 dB(A)
Energy consumption at 25°C and 60% RH 1,000 Wh/h 1,000 Wh/h
Fixtures
Designation MKF115-400V MKF115-480V-C
Number of shelves (std./max.)
1/4

1/4
Binder Constant Climate Chambers | MKF 115 Images

Binder Constant Climate Chambers | MKF 56Binder Constant Climate Chambers | MKF 56Binder Constant Climate Chambers | MKF 56

 

Binder Dynamic Climate Chambers | MKF 115 MKF 115
Binder Dynamic Climate Chambers | MKF 115

Recommend

*
*
*