Binder Safety Drying Chambers for Limited Quantities of Solvent | FDL 115

Stock Code
FDL 115
Benefits
  • Safety concept meets the DIN EN 1539-2010-08 standard
  • Short drying time with high temperature accuracy and defined ventilation
  • Silicone free and dust-free inner chamber
  • Replaceable fresh air cartridges are easy to change and ensure constant fresh air quality
binder, binder sales, binder azerbaycan
Binder Safety Drying Chambers for Limited Quantities of Solvent | FDL 115

  The BINDER FDL 115 with silicone and dust-free inner chamber, as well as symmetric airflow dries specimens containing solvents and thus this safety drying oven meets all EN 1539 requirements.

Binder Safety Drying Chambers for Limited Quantities of Solvent | FDL 115

Binder Safety Drying Chambers for Limited Quantities of Solvent | FDL 115 General Information

- Temperature range:
• +10°C above ambient temperature to
• +300 °C
- APT.line™ preheating chamber technology
- Controller with time-segment and real-time programming
- 2 chrome-plated racks
- Fresh-air monitoring with audible and visual alarm and automatic deactivation of heating
- Replaceable filter cartridge, Class M6
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
- Computer interface:
RS 422
- Standard door gasket made from solvent-resistant FKM for use at up to 200 °C
- Optional door gasket made from silicone with limited solvent resistance for use at up to 300 °C

Data

Designation FDL115-230V
Article Number 9010-0292
Option model

Standard

Performance Data Temperature
Designation FDL115-230V
Temperature range +10 °C above ambient temperature to 300 °C
Temperature uniformity at 150°C 2.5 ± K
Temperature fluctuation at 150°C 0.8 ± K
Heating up time to 150°C 20 min
Recovery time after door was opened for 30 s at 150°C 12 min

Air Change Data

Designation FDL115-230V
Air circulation (approx.) 20 x/min
Volumetric flow rate of exhaust air acc. to EN 1539 at 50 °C 400 ca. L/min
Solvent Quantity

Designation FDL115-230V
Highest permitted solvent quantity (at T-180°C, M-100g/mol, U-40g/m3, K=0,5)
4,67 g

Electrical Data
Designation FDL115-230V
Rated Voltage 230 V
Power frequency 50/60 Hz
Nominal power 2,9 kW
Phase (Nominal voltage) 1~

Measures

Designation FDL115-230V
Interior volume 115 L
Net weight of the unit (empty) 90 kg
Load per rack 30 kg
Permitted load 60 kg
Wall clearance back 160 mm
Wall clearance sidewise 100 mm

Housing dimensions not incl. fittings and connections

Designation FDL115-230V
Width net 830 mm
Height net 805 mm
Depth net 685 mm

Internal Dimensions

Designation FDL115-230V
Interior width 600 mm
Interior height 435 mm
Interior depth 435 mm

Environment-specific data
Designation FDL115-230V
Sound-pressure level 57 dB(A)
Energy consumption at 150°C 1,200 Wh/h

Fixtures
Designation FDL115-230V
Number of shelves (std./max.) 2/5
Binder Safety Drying Chambers for Limited Quantities of Solvent | FDL 115 Images

Binder Safety Drying Chambers for Limited Quantities of Solvent | FDL 115Binder Safety Drying Chambers for Limited Quantities of Solvent | FDL 115Binder Safety Drying Chambers for Limited Quantities of Solvent | FDL 115
Binder Safety Drying Chambers for Limited Quantities of Solvent | FDL 115 FDL 115
Binder Safety Drying Chambers for Limited Quantities of Solvent | FDL 115

Recommend

*
*
*