Binder Vacuum Drying Chambers for Flammable Solvents | VDL 115

Stock Code
VDL 115
Benefits
  • Fast, gentle drying
  • Optimum heat transfer through large thermal conducting plates
  • Safe working thanks to ATEX-compliant safety concept
  • Also option of modular complete system with vacuum pump and pump chamber
binder, binder sales, binder azerbaycan
Binder Vacuum Drying Chambers for Flammable Solvents | VDL 115

  BINDER VDL series safety vacuum drying chambers ensure maximum safety when drying organic solvents. Explosion-protected unit with classification according to ATEX directive 2014/34/EU: EX II 2/3/- G IIB T3 Gb/Gc/- X.

Binder Vacuum Drying Chambers for Flammable Solvents | VDL 115

 

Binder Vacuum Drying Chambers for Flammable Solvents | VDL 115 General Information
- Temperature range: +9°C above ambient temperature to +110 °C
ATEX conformity for units: EX II 2/3/- G IIB T3 Gb/Gc/- X
- Intuitive touchscreen controller with graphical pressure and temperature display
- Program-controlled drying monitoring with automatic ventilation at end of process
- Internal data logger, measured values can be read out in open format via USB
- Pressure control device for heating activated from < 100 mbar
- 2 aluminum expansion racks, can be custom-positioned
- Universal connection for ventilation with ambient air or inert gas
- Universal access port DN 16 - for the introduction of external measuring devices
Shatterproof, spring-mounted safety glass panel
- Large viewing window
- Computer interface: Ethernet


Binder Vacuum Drying Chambers for Flammable Solvents | VDL 115 Technical Data

Data

Designation VDL115-230V

VDL115-120V

Article Number 9630-0011 9630-0015
Option model

Standard

Standard

Performance Data Temperature
Designation VDL115-230V

VDL115-120V

Temperature range +9 °C above ambient temperature to 110 °C +9 °C above ambient temperature to 110 °C
Temperature uniformity at 100°C 2.9 ± K 2.9 ± K
Temperature fluctuation at 100°C 0.1 ± K 0.1 ± K
Heating up time to 100°C 170 min 170 min

Vacuum Data

Designation VDL115-230V

VDL115-120V

Leckrate 0,01 bar/h 0,01 bar/h

Electrical Data

Designation VDL115-230V

VDL115-120V

Rated Voltage 200...230 V 100...120 V
Power frequency 50/60 Hz 50/60 Hz
Nominal power 1,6 kW 1,6 kW
Unit fuse 10,0 A 20,0 A
Phase (Nominal voltage) 1~ 1~
Connections
Designation

VDL115-230V

VDL115-120V

Vacuum connection with small flange 16 DN mm 16 DN mm
Measuring access port with small flange 16 DN mm 16 DN mm
Measures
Designation

VDL115-230V

VDL115-120V

Interior volume 119 L 119 L
Net weight of the unit (empty) 158 kg 158 kg
Load per rack 20 kg 20 kg
Permitted load 70 kg 70 kg
Wall clearance back 100 mm 100 mm
Wall clearance sidewise 70 mm 70 mm

Housing dimensions not incl. fittings and connections

Designation VDL115-230V VD115-120V
Width net 743 mm 743 mm
Height net 942 mm 942 mm
Depth net 581 mm 581 mm
Internal Dimensions
Designation VDL115-230V VDL115-120V
Interior width 506 mm 506 mm
Interior height 506 mm 506 mm
Interior depth 460 mm 460 mm
Viewing window width 525 mm 525 mm
Viewing window height 468 mm 468 mm
Unit doors 1 1
Environment Specific Data
Designation VDL115-230V

VDL115-120V

Sound-pressure level 40 dB(A) 40 dB(A)
Energy consumption at 100°C 230 Wh/h 230 Wh/h
Fixtures
Designation VDL115-230V

VDL115-120V

Number of shelves (std./max.) 2/6 2/6
Binder Vacuum Drying Chambers for Flammable Solvents | VDL 115 Images

VDL-115VDL-115

Binder Vacuum Drying Chambers for Flammable Solvents | VDL 115 VDL 115
Binder Vacuum Drying Chambers for Flammable Solvents | VDL 115

Recommend

*
*
*