Benefits
  • Stable and uniform environment
  • Fully complies with Pharma regulations (ICH)Equipment
  • Longevity - corrosion resistant
  • Ease of operation
  • Environmental friendly refrigerant with GWP value 547
  • Maintenance possible with the least possible disruption to the climate conditioning
  • Perfectly meets requirements in Pharma industry
  • 3 years warranty

Binder Walk-in Chambers  ICH (Q1A) | WIC 2

   The walk-in-chambers offer a wide range of features and benefits to perfectly meet requirements in stability testing. Perfect test conditions are maintained in a wide range of temperature from 10°C to 50°C and relative humidity of 20% to 90% RH.

Binder Walk-in Chambers  ICH (Q1A) | WIC 2

Binder Walk-in Chambers  ICH (Q1A) | WIC 2 General Information

- Relative humidity accuracy of ± 2.5%
- Temperature accuracy of ± 1.5°C
- Duct work for proper distribution of air
- Highly insulated room panels with U value of only 0,21 W/m2K
- LED Lighting with motion detector
- High quality room elements, made in Germany
- Interior completely stainless steel
- Exterior service accessibility
- Room Elements: Galvanized sheet steel, polyester coated, white, similar to RAL 9010, interior surfaces in stainless steel,4 inch / 100 mm PU foam U value 0,21W/m2K
Floor: Floor overlay is chrome-nickel steel, pattern-rolled 5WL
Surface load: 50.000 N/m2

Binder Walk-in Chambers | ICH (Q1A) Technical Specifications
Data
Designation

WIC2-230V

WIC2-208V

WIC2C-208V

Article Number 9800-0012 9800-0003 9800-0004
Option model

Standard

Standard

with conditioner on ceiling

Performance Data Climate
Designation

WIC2-230V

WIC2-208V

WIC2C-208V

Temperature range with humidity 10...50 °C 10...50 °C 10...50 °C
Temperature uniformity at 25°C and 60% RH 1.5 ± K 1.5 ± K 1.5 ± K
Temperature uniformity at 40°C and 75% RH 1.5 ± K 1.5 ± K 1.5 ± K
Temperature fluctuation at 25°C and 60% RH 0.5 ± K 0.5 ± K 0.5 ± K
Temperature fluctuation at 40°C and 75% RH 0.5 ± K 0.5 ± K 0.5 ± K

Electrical Data
Designation

WIC2-230V

WIC2-208V

WIC2C-208V

Rated Voltage 230 V 208...230 V 208...230 V
Power frequency 50 Hz 60 Hz 60 Hz
Nominal power 2,7 kW 2,7 kW 2,7 kW
Unit fuse 20,0 A 20,0 A 20,0 A
Phase (Nominal voltage) 1~ 1~ 1~
Measures
Designation

WIC2-230V

WIC2-208V

WIC2C-208V

Interior volume 18,523 L 18,523 L 18,523 L
Net weight of the unit (empty) 981 kg 981 kg 981 kg
Housing Dimensions Not Incl. Fittings and Connections
Designation

WIC2-230V

WIC2-208V

WIC2C-208V

Width net 2,600 mm 2,600 mm 2,600 mm
Height net 2,470 mm 2,470 mm 2,470 mm
Depth net 3,600 mm 3,600 mm 3,600 mm

Internal Dimensions
Designation

WIC2-230V

WIC2-208V

WIC2C-208V

Interior width 2,400 mm 2,400 mm 2,400 mm
Interior height 2,270 mm 2,270 mm 2,270 mm
Interior depth 3,400 mm 3,400 mm 3,400 mm
Unit doors 1 1 1
Environment-specific Data
Designation

WIC2-230V

WIC2-208V

WIC2C-208V

Energy consumption at 40°C and 75% RH
1,140 Wh/h

1,140 Wh/h

1,140 Wh/h