Binder Dynamic Climate Chambers | MKFT 115

Stock Code
MKFT 115
Benefits
  • Homogeneous climate conditions thanks to APT.line™ technology
  • Automatic water and wastewater management
  • Pressure humidification with fast response times
  • Comprehensive programming and data acquisition
  • Large heated viewing window
binder, binder sales, binder azerbaycan
Binder Dynamic Climate Chambers | MKFT 115

   The BINDER MKFT series environmental simulation chamber for low temperature alternating climate profiles is the specialist for dynamic alternating climate change between -70 °C and 180 °C. Large performance reserves and rapid cooling make the MKFT environmental simulation chamber the high-end product for complex standards-based climate tests.

Binder Dynamic Climate Chambers | MKFT 115

Binder Dynamic Climate Chambers | MKFT 115 General Information

- Temperature range: -70°C above ambient temperature to +180 °C
Humidity range: 10 % to 98 % RH
- Integrated water-storage tank, 20 liters
4 zero-voltage relay contacts
- APT.line™ preheating chamber technology
- Programmable condensation protection for test material
- Intuitive touchscreen controller with time-segment and real-time programming
- Internal data logger, measured values can be read out in open format via USB
Heated viewing window with LED interior lighting
Humidity regulation with capacitative humidity sensor and vapor humidification
BINDER Multi Management Software APT-COM™ Basic Edition
Troubleshooting system with visual and audible alarms
- Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm
Access port with silicone plug: 50 mm, left
- 4 castors, two with brakes
Computer interface: Ethernet
Adjustable ramp function
- Integrated chart recorder
- Real-time clock
- Door heating
- 1 stainless steel rack
- Alarm notification in the event of insufficient water in fresh water tank
- Complete safety connection kit for water supply and drainage, up to 1 m in height
- Inner chamber made of stainless steel
- CFC-free refrigerants R-452A and R-23
- Cooling with cascade compressor cooling unit


Binder Constant Climate Chambers | MKFT 115 General Information
Data

Designation MKFT115-400V MKFT115-480V-C
Article Number 9020-0382 9020-0362
Option model

Standard

with voltage and frequency converter

Performance Data Temparature
Designation MKFT115-400V MKFT115-480V-C
Temperature range -70...180 °C -70...180 °C
Temperature uniformity dependent on set value 0.1...1.3 ± K 0.1...1.3 ± K
Temperature fluctuation dependent on set value 0.1...0.1 ± K 0.1...0.1 ± K
Average heating-up rate according to IEC 60068-3-5 5.5 K/min 5.5 K/min
Cooling down time from 180°C to -70°C 120 min 120 min
Average cooling down time according to IEC 60068-3-5 4.2 K/min 4.2 K/min
Performance Data Climate
Designation MKFT115-400V MKFT115-480V-C
Temperature range with humidity 10...90 °C 10...90 °C
Humidity range 95 % RH...10 95 % RH...10
Temperature fluctuation with humidity dependent on set value 0.1...1 ± K 0.1...1 ± K
Humidity fluctuation with humidity dependent on set value ≤2,5 ± % r.F. ≤2,5 ± % r.F.
Max. heat compensation at 25°C and 90% RH 400 W 400 W
Electrical Data
Designation MKFT115-400V MKFT115-480V-C
Rated Voltage 400 V 480 V
Power frequency 50 Hz 60 Hz
Nominal power 5 kW 5 kW
Unit fuse 16,0 A 16,0 A
Phase (Nominal voltage) 3~ 3~

Measures

Designation

MKFT115-400V

MKFT115-480V-C

Interior volume 115 L 115 L
Net weight of the unit (empty) 330 kg 330 kg
Load per rack 30 kg 30 kg
Permitted load 60 kg 60 kg
Wall clearance back 300 mm 300 mm
Wall clearance sidewise 200 mm 200 mm
Housing dimensions not incl. fittings and connections
Designation MKFT115-400V MKFT115-480V-C
Width net 980 mm 980 mm
Height net 1,725 mm 1,725 mm
Depth net 865 mm 865 mm
Internal Dimensions
Designation MKFT115-400V MKFT115-480V-C
Interior width 600 mm 600 mm
Interior height 480 mm 480 mm
Interior depth 400 mm 400 mm
Unit doors 1 1
Environment-specific data
Designation MKF1020-400V MKF1020-480V-C
Sound-pressure level 64 dB(A) 64 dB(A)
Energy consumption at 25°C and 60% RH 1,000 Wh/h 1,000 Wh/h
Fixtures
Designation MKFT115-400V MKFT115-480V-C
Number of shelves (std./max.) 1/4 1/4


Binder Constant Climate Chambers | MKFT 115 Images

Binder Constant Climate Chambers | MKFT 115Binder Constant Climate Chambers | MKFT 115
Binder Dynamic Climate Chambers | MKFT 115 MKFT 115
Binder Dynamic Climate Chambers | MKFT 115

Recommend

*
*
*